Service Details:
Model Name/Number | Spectro Genesis |
Photometric Repeatability | +- 0.2% T |
Stability | +- 0.001 A/h. |
Display | LCD |
Voltage | 220 |
Usage/ Application | Laboratory use |
List No. | r |
Country of Origin | Made in India |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationModel | Spectrogreen |
Warmup Time | ~10 minutes |
Analysis Speed | 100 ms |
Specific Protocols | U.S. EPA 200.7,CLP ILM 5.3,and CLP ISM 2.3 |
Brand | Spectro |
Product Type | ICP-OES Spectrometers |
SPECTROGREEN inductively coupled plasma optical emission spectrometer (ICP-OES) with new revolutionary Dual Side-On Interface (DSOI) technology
SPECTRO’s new DSOI technology, a brand-new approach to the critical issue of plasma view design, uses a vertical plasma torch, observed via a new direct radial-view technology. Two optical interfaces capture emitted light from both sides of the plasma, using only a single extra reflection, for added sensitivity and elimination of issues plaguing newer vertical-torch dual-view models. As a result, DSOI provides twice the sensitivity of conventional radial systems — yet avoids the complexity, drawbacks, and cost of vertical dual view models.
SPECTROGREEN analysis delivers significant advantages in determining trace elements and handling samples with challenging matrices, including certain wastewaters, soils, and sludges, industrial chemicals, high salt samples, and metals. The SPECTROGREEN spectrometer is ideal for routine analyses in environmental and agronomy applications, as well as consumer product safety; pharmaceuticals; petrochemicals; chemicals; and foods.
SPECTROGREEN leverages more than 30 years of benchmark service and experience in inductively coupled plasma optical emission (ICP-OES, ICP-AES also ICP plasma) spectroscopy.
The SPECTROGREEN ICP-OES system comes equipped with SPECTRO’s proprietary ICP ANALYZER PRO software, making it easy to take full advantage of the instrument’s simplified operation and unique analytical capabilities.
Additional optical emission spectroscopy instruments in SPECTRO’S comprehensive ICP-OES product line include SPECTRO GENESIS, SPECTROBLUE and SPECTRO ARCOS.
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Wavelength Range | 190-900 nm |
Spectral Bandwidth | 2 nm |
Brand | Analytik Jena |
Model No / Item Code | Nova AA 800 |
Usage / Application | Laboratory Use |
Material | Stainless steel |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
CHARACTERISTICSTypeatomic absorptionFieldfor laboratories, for industrial applications, for food analysis, for metal analysis, for agricultural applications, for mining applications, cost-effective, for environmental analysis, chemicalOther characteristicsautomated, robust, high-speedDESCRIPTIONThe analyzer for you – high-performance AAS for routine laboratories - Cost-effective – top performance at low investment and operating costs - Simple – easy handling thanks to user-friendly concepts - Reliable – stable measuring conditions due to robust components and clever design - Powerful – high throughput due to integrated sampling and dilution The efficient workhorse for your lab novAA 800 is the perfect AAS for routine use in industrial QC laboratories and analytical service providers. It combines versatility, reliability, and automation, making it a highly efficient and cost-effective workhorse for your laboratory. - Reliable with a 10-year long-term warranty on optical components - Improved workflow due to simplified operations and high degree of automation - Performance-enhancing accessories for efficient analysis - AAS applications - flame, graphite furnace, and hydride technology – all on one platformIntellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Wavelength Range | 190-900 nm |
Model Name/Number | NIRS(TM) DS3 |
Weight | 27 kg |
Display | Digital |
Voltage | 100-240 V AC |
Analysis time | <1 minute for 32 scans |
Service Details:
Brand | Thermofisher |
Wavelength Accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Stray Light | Less than equal to 0.1%T |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationModel Name/Number | Multiskan SkyHigh |
Brand | Thermo Scientiic |
Wavelength Range | 200-1000 nm with 1 nm steps |
Band Width | <2.5 nm |
Dimensions | 265 x 295 x 445 mm |
Weight | 11.3 kg (24.9 lbs.) |
Light Source | Xenon flash lamp |
Wavelength Resolution | Monochromator |
Read Out | Up to 3 Abs |
Connections | 1 USB B port for PC,1 Ethernet port,3 USB A ports for devices |
Measurement Speed | 6 seconds with 96-well plate |
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Brand | Thermo Fisher |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.2% T |
Stability | +- 0.002 A/h. |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Mobility | Fixed |
Brand | Thermo Fisher |
Model Name/Number | ISQ7K-VPI |
Mass Range | 1.2 to 1100 U with Unit Mass Resolution |
Detector | Triple Off-Axis Thermo Scientific DynaMax XR with Electronic Dynamic Range > 109 |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
Mass Filters | Dual-Stage Mass Filter with Off-Axis Ion Guide Pre-Filter for Noise Reduction |
Scanning Capabilities | Fast Quadrupole Scanning up to 20000 U/s |
Source Type | Ultra-Inert ExtractaBrite Ion Source for Standard Operation,and Advanced Electron Ionization (AEI) |
Experience unstoppable routine analyses easily, consistently and reliably over time, in compliance with the most demanding legislation requirements.
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Brand | Thermo Fisher |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Stability | +- 0.002 A/h. |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationMobility | Fixed |
Brand | Thermo Fisher |
Model Name/Number | ISQ Series |
Mass Range | 1.2 to 1100 U with Unit Mass Resolution |
Detector | DynaMax XR |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
Electron Energy | Adjustable From 0 to 150 eV |
Reagent Gas | Software-Switchable Dual Reagent Gas with Digital Flow Control |
Scanning Capabilities | Scan Rate Up to 20,000 U/Sec; Scan Cycles 97 Scans/Sec to Disc When Scanning Across 125 U |
Mass Filter | Dual-Stage Mass Filter with Off-Axis Ion Guide and Solid,Homogeneous Non-Coated Quadrupole Rods |
Warranty | 1 year |
U.S. EPA target tune capability using TraceFinder EFS.
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Brand | Thermo Fisher |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Lamp Type | Tungsten Halogen Lamp |
Stability | +- 0.002 A/h. |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationMobility | Fixed |
Ambient Temperature | 12 Deg C to 25 Deg C (12 Deg C to 35 Deg C optional) |
Brand | Thermo Fisher |
Model Name/Number | Sentinel Pro Environmental Mass Spectrometer |
Sensitivity | superior accuracy |
Power | 115/230VAC,consumption 1500VA |
Usage/ Application | Laboratory use |
Weight | 300kg,0.7m |
Additional Available Protocols | Modbus+,Allen Bradley DH,Allen Bradley DH+,Profibus |
Stability | Better than 10% relative over 1 month (no calibration) |
Analysis Time | 0.3 to 1.0 seconds per gas component (configurable by software) |
Communication Protocols | Modbus,Siemens 3964,Siemens 3964R,VGCP,PVGCP |
Height | 0.65m |
Length | 1.5m |
Scanning Magnetic Sector Measurement Method | Scanning magnetic sector mass spectrometer |
Precision | All readings within 0.5ppm of calibrated value (24 hours) |
Serial Connections | RS232/422/485 |
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Lamp Type | Tungsten Halogen Lamp |
Stability | +- 0.002 A/h. |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationMobility | Fixed |
Brand | Thermo Fisher |
Resolution | 50,000 (at m/z 272) |
Mass Accuracy | Internal <1 ppm RMS; External <3ppm RMS |
Dynamic Range | Quantitative >106,In-Spectrum >50001 |
Mass Range | 30 to 3,000 m/z |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
MS Scan Power | up to 18 Hz at resolution setting of 12,500 at m/z 272 |
The Exactive GC system is an easy-to-use, dedicated GC-MS that provides an unprecedented level of highly sensitive, routine grade performance for both targeted and non-targeted analysis, along with high confidence quantitation for the ultimate sample analysis workflow. This is achieved through the superior resolving power, mass accuracy, linear dynamic range and sensitivity that only Orbitrap technology can deliver, combined with the intelligent data processing workflows provided by Thermo Scientific™ TraceFinder™ software.
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Mobility | Fixed |
Sensitivity | superior accuracy |
Weight | 50 kg |
Usage/ Application | Laboratory use |
Height | 50.0 cm |
Service Details:
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.1% T |
Photometric Repeatability | +- 0.2% T |
Lamp Type | Deuterium Lamp |
Stability | +- 0.001 A/h. |
Detector | Silicon Photodiode |
Usage/ Application | Laboratory,Industrial use |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationOptical System | Double Beam |
Spectral Bandwidth | 2 nm |
Mobility | Benchtop |
Brand | Thermo Fisher |
Model Name/Number | ARL iSpark |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
Type | Optical Emission Spectrometer |
Generator | Revolutionary Digital Spark |
Testing Material | Metal |
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Lamp Type | Hollow Cathode Lamps |
Brand | Shimadzu |
Wavelength Accuracy | +-0.3 nm |
Wavelength Repeatability | +-0.1 nm |
Photometric Accuracy | +- 0.1% T |
Service Details:
Brand | Jasco |
Model No / Item Code | FP-8000 |
Wavelength Accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Repeatability | +- 0.3% T |
Dimensions | 570(W) x 545(D) x 270(H) mm |
Wavelength Resolution | +-1.0 nm+-2.0 nm |
Resolution | 2.5NM /1.0NM |
Weight | 39 kG |
List No. | r |
Country of Origin | Made in India |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product DescriptionIntellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number | r |
Disclaimer | UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Mobility | Portable |
Model Name/Number | QSight |
Sensitivity | superior accuracy |
Weight | Around 100 kg |
Usage/ Application | Laboratory,Industrial use |
Brand | PerkinElmer |
Size | 120 x 50 x 50 cm or 48 x 20 x 20 in |
Service Details:
Mobility | Benchtop |
Model Name/Number | Avio 220 Max Scott/Cross-Flow |
Sensitivity | superior accuracy |
Weight | 100.0 kg |
Usage/ Application | Laboratory use |
List number: - R
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified.
meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer.
Service Details:
Wavelength Range | 325-1000 nm |
Optical System | Double Beam |
Spectral Bandwidth | 2 nm |
Mobility | Fixed |
Brand | Spectro Ametek |
Model Name/Number | MS |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationBrand | Spectro |
Product Type | MS ICP-MS Spectrometers |
Dimensions | HxWxD) 1604 x 1673 x 892 mm (63 x 66 x 35 inch) |
Footprint Dimensions | WxD) 1470 x 779 mm,(58 x 31 inch) |
Weight Approx | 75 kg,(1490 lbs) |
Room Temperature | 8-25 Degree C (67-77 Degree F) |
Relative Humidity | Less Then 80% non-condensing |
Atmosphere | free of corrosive vapors and high dust pollution |
Consumption | 0-18 L/min |
Pressure | bar (58 psi) |
The ICP-MS with maximum flexibility
The ICP-MS that leads in productivity
The ICP-MS with precision and accuracy
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Brand | Analytik Jena |
Model No / Item Code | ScanDrop 2 |
Wavelength Accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.2% T |
Lamp Type | Xenon Lamp |
Measuring Time | < 2 s |
Optimum | CCD detector |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
scandrop2 – maximum flexibility in uv/vis spectrophotometry
intellectual property: trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
list number |
r |
disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. However, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appears with the listed products, it is only used for the purpose of identification of those products. We do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturere. |
Additional Information:
Service Details:
Wavelength Range | 190-850 nm |
Optical System | Single Beam |
Spectral Bandwidth | 2 nm |
Mobility | Portable |
Brand | Thermo Scientific |
Model No / Item Code | NanoDrop One |
Wavelength Accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Detector | 2048-element CMOS linear image sensor |
Display | 7-inch,1280 x 800 high-definition color display |
Dimensions | 20 x 25.4 x 32.3 cm |
List No. | r |
Country of Origin | Made in India |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationBrand | Thermo Scientific |
Display | 7-inch,1280 x 800 high-definition color display |
Wavelength Range | 190-850 nm |
Detector | 2048-element CMOS linear image sensor |
Dimensions | 20 x 25.4 x 32.3 cm (8 x 10 x 12.7 in.) |
Weight | 7.9 lbs. |
Move one step closer to your research goals with an ergonomic, standalone spectrophotometer with high-resolution, touch screen interface. Powerful auto-range pathlength technology facilitates accurate measurements for concentrated samples with no need for dilutions. This is your innovative alternative to the NanoDrop 2000/2000c Spectrophotometers.
NanoDrop One/Nanodrop OneC PC Software with 21 CFR Part 11 Compliance
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Brand | LS 45 |
Usage/ Application | Laboratory use |
Spectrometer Type | Fluorescent |
Electrical Specifications | 120 V,1 A,200 W,1 Ph,50/60 Hz |
List No. | r |
21 CFR Part 11 | Yes |
Weight, Product | 50 kg |
Dimensions, Product | 889 mm W x 508 mm D x 762 mm H |
Country of Origin | Made in India |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Modes: Fluorescence, Phosphorescence and Bio-and Chemiluminescence
• Pulse Xenon Lamp reduces photo bleaching for long-lived excitation
• Includes FL WinLab, single cell holder and semi-micro cuvettes
• Wave Length from 200 nm to 800 nm and UV/Vis technology type
• One-Year Manufacturer Warranty
• Fixed slits, ideal for daily use
• Measurement modes:
• 3D Excitation/Emission (EEM) and 3D synchronous scanning
• 3D kinetic scanning
• Single- and multiple-wavelength kinetics
• Simple quantitation by curve fitting with a number of fit algorithms
• Intracellular ion analyses
• Polarization
• Pulsed Xenon Lamp features and benefits:
• Minimal photo bleaching of samples
• Long-lived excitation for stability and accuracy
• Improved low-light detection capability compared to other light sources
• Wide UV output (to 200 nm) provides greater flexibility when selecting excitation wavelengths
• Replaceable pre-aligned bulb eliminates replacement of entire lamp module
• Delay and gate time varied to measure phosphorescence
• Can be turned off when measuring chemiluminescence and bioluminescence
• FL WinLab Software features:
• Accesses Scan, Time Drive and Ratio Data Collection from Applications Menu
• Validation protocol automatically checks instrument performance ideal for labs complying with GLP
• Plug-in application modules include:
• Short phosphorescence decay routine, enzyme-activity program, WPR Scan (allows well-plate reader to scan multiple spectra per well, autopol (for programmed measurement of intensity, polarization or anisotropy vs. temperature
• Variety of advanced three-dimensional data-handling, presentation and export routines
Show less
• Spectrometer Type: Fluorescent
• Brand: LS 45
• 21 CFR Part 11: Yes
• Manufacturer SKU: L2250116
• Unit of Measure: EA
• Electrical Specifications: 120 V, 1 A, 200 W, 1 Ph, 50/60 Hz
• Weight, Product: 50 kg
• Dimensions, Product: 889 mm W x 508 mm D x 762 mm H
• Weight, Shipping: 68 kg
• Dimensions, Shipping: 1,041 mm W x 635 mm D x 889 mm H
• Package Type: Box
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Brand | Bruker |
Model Name/Number | FTIR,Lumos II |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Usage/ Application | For Hospital Use |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product Specification
Model Name/Number | Lumos II |
Brand | Bruker |
Material | Aluminium |
Measurement Mode | Transmission,Reflection,and ATR |
Spectral Resolution | 1 micron |
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Lamp Type | Deuterium Lamp |
Stability | +- 0.002 A/h. |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationMobility | Benchtop |
Spectral Resolution | Better than 4 cm-1 |
Brand | Thermo Fisher |
Model Name/Number | Nicolet iS 5N FT-NIR Spectrometer |
Wavelength accuracy | 0.01 cm-1 at 5300 cm-1 |
Weight | 22 lbs,10 kg |
Certifications | CE,ETL |
Electrical Requirements | USB 2.0 high-speed bidirectional communication to PC |
Signal To Noise Ratio | 10 uABS RMS in less than a minute |
Self Diagnostics | Automatic accessory recognition Temperature Humidity |
Width | 13.5 in.,35 cm |
Height | 10.2 in.,26 cm |
Beam Splitter | CaF2 near-infrared |
Laser | Temperature stabilized solid-state Near-IR diode laser |
Depth | 0.9 in.,28 cm |
Source Type | High intensity halogen NIR; user replaceable from bottom plate |
Spectral Range | 11,000-3800 cm-1 optimized,CaF2 beamsplitter |
Detector Type | Extended range indium gallium arsenide (InGaAs) |
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Lamp Type | Tungsten Halogen Lamp |
Stability | +- 0.002 A/h. |
List No. | r |
Country of Origin | Made in India |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationMobility | Benchtop |
Brand | Thermo Fisher |
Model Name/Number | PicoSpin 80 Series II NMR Spectrometer |
Country of Origin | Made in India |
Performance | Larmor Frequency 82 +/- 2 MHz Proton; Chemical Shift Resolution 20 ppb FWHM or Better |
Magnet | Rare Earth Permanent; 2 Tesla; Temperature Stabilized |
Sample | Sample Type Liquid |
Power Consumption | 100-230 VAC,50/60 Hz,150 W |
Weight | 43 lb.,19 kg |
The picoSpin 80 Series II NMR spectrometer offers simplified workflows, a modern interface and automatic shimming plus custom methods; perfect for the novice or experienced users alike. It enables students and technicians with limited NMR experience to use the power of NMR spectroscopy to identify chemical compounds or elucidate their structure. The instrument’s fluid capillary system is contained within a replaceable cartridge and only requires 40 microliters of a liquid sample. Its temperature-controlled permanent magnet does not require cryogens, eliminating the need for consumables or custom laboratory facilities.
This affordable, benchtop instrument offers:
Applications:
Pharmaceutical:
Time efficiency means everything in a busy lab, so why wait hours for NMR data from the central facility. At 82 MHz the picoSpin 80 NMR spectrometer delivers chemical shift dispersion and resolution unmatched by other desktop NMR systems at 60 MHz and below. Whether it is distinguishing a product from a reactant or calculating reaction yield, the picoSpin 80 spectrometer delivers more clarity and confidence for fast decisions.
Improve Productivity:
Optimize Your Plant or Factory Workflow:
List number |
r |
Disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Mobility | Portable |
Weight | 13.0 kg |
Brand | Spectrum Two N |
Height | 21.0 cm |
Technology Type | Infrared |
Research Areas | Food & Agriculture |
Service Details:
Material | Plastic |
Wavelength accuracy | +-0.3 nm |
Wavelength Repeatability | +-0.1 nm |
Photometric Repeatability | +- 0.2% T |
Lamp Type | Tungsten Halogen Lamp |
Stability | +- 0.001 A/h. |
Detector | Silicon Photodiode |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product Features:
Meets curriculum topics for:
Lab associate benefits:
List number: - r
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified.
meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer.
Additional Information:
Service Details:
Wavelength Range | +- 0.5 nm |
Wavelength accuracy | +-0.3 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +- 0.3% T |
Photometric Repeatability | +- 0.3% T |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
The NexION 1000/2000 ICP-MS (Inductively Coupled Plasma Mass Spectrometer) is an advanced analytical instrument designed for elemental analysis in laboratory settings. Here's an overview of what you can expect from these instruments:
Inductively Coupled Plasma (ICP): The ICP serves as the ionization source in the mass spectrometer. It ionizes the sample by subjecting it to a high-temperature plasma, typically generated using argon gas. This process atomizes and ionizes the sample, creating a plasma that is rich in ions.
Mass Spectrometry (MS): In the NexION 1000/2000 ICP-MS, the ionized sample is then introduced into the mass spectrometer, where it is separated based on mass-to-charge ratio (m/z). This separation allows for the identification and quantification of individual elements present in the sample.
Key Features:
Service Details:
Mobility | Fixed |
Model Name/Number | NexION 1000 |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Weight | 150 kg |
Service Details:
Model Name/Number | Two N FT-NIR |
Brand | PerkinElmer |
Material | Mild Steel |
Voltage | 220 V |
Usage/ Application | Laboratory |
Height | 21.0 cm |
Depth | 30.0 cm |
Detector Type | LiTaO3 |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
High Performance FT-NIR That Goes Where You Go
Spectrum Two N FT-NIR spectrometer distills 75 years of PerkinElmer spectroscopy into a compact, high-performance yet robust FT-NIR. Simple to use, dependable and adaptable with optimized “plug-and-play” sampling accessories and modules coupled with a comprehensive software platform, Spectrum Two N systems are suited to a wide range of applications. Whatever your specific NIR application needs, in or out of the lab, the Spectrum Two N delivers outstanding performance and reliability to provide high-performance, dependable NIR measurement solutions.
Spectrum Two N FT-NIR spectrometers feature:
For Every Application
PerkinElmer recognizes that every application is different. The result is a complete solution to provide the fastest assurance of the quality of your materials, regardless of the application. Some of the industry applications that the Spectrum Two N is designed to accommodate include:
For these specific applications, we offer various “plug-and-play” sampling accessories and modules enhancing the versatility of the Spectrum Two N FT-NIR.
Specifications21 CFR Part 11 Compatible | Yes |
---|---|
Depth | 30.0 cm |
Detector Type | LiTaO3 |
Height | 21.0 cm |
Operating Range | 5 - 45 °C |
Portable | Yes |
Product Brand Name | Spectrum Two N |
Product Group | Instrument |
Research Areas | Food & Agriculture |
Warranty | 1 Year |
Weight | 13.0 kg |
Width | 45.0 cm |
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number | r |
Disclaimer | UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Brand | Spectro Ametek |
Model Name/Number | CUBE |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory,Industrial use |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationBrand | Spectro |
Product Type | Spectrocube XRF Spectrometers |
Detector | Silicon Drift Detector (SDD) |
Excitation | 40 W X-ray tube,molybdenum (Mo) anode,50 kV max. |
Height | 380 mm (15 in) |
Width | 520 mm (20.5 in) |
Depth | 540 mm (21.3 in) |
Weight | ca. 48 kg (~ 106 lbs) |
Sample Chamber | Video system to display sample image HxWxD 155 x 400 x 320 mm (6.1 x 15.7 x 12.8 in) |
Evaluation System | External computer system; Windows operating system Keyboard,mouse,monitor,printer |
Power Supply | Operating voltage 95-120 V / 200-240 V 50/60 Hz ower consumption of spectrometer 120 W |
Analyses | F undamental Parameters program FP+ for elemental analysis of alloys |
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number | r |
Disclaimer | UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Wavelength Range | 190-1100 nm |
Brand | PerkinElmer |
Model No / Item Code | LAMBDA 365 |
Warranty | 1 Year |
Weight | 20.0 kg |
Width | 49.0 cm |
Service Details:
Brand | Spectro Ametek |
Model Name/Number | Scout |
Wavelength accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Sensitivity | superior accuracy |
Usage/ Application | Laboratory use |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product Specification
Brand | Spectro |
Product Type | Spectroscout XRF Spectrometers |
Detector | Si-PIN |
Excitation | X-ray tube,rhodium (Rh) anode,50 kV max. |
Height | Transport position 270 mm (10.7 in),Operation position 350 mm (13.8 in) |
Width | 306 mm (12.1 in) |
Depth | 306 mm (12.1 in) |
Weight | 11 kg (24.251 lb) excluding battery pack,11.75 kg (25.904 lb) including battery pack |
Power Supply | Operating voltage 10-30 V DC,Integrated 4+ hours Li- ion battery pack |
Hardware | Integrated PC with touchscreen Bluetooth,wireless LAN,USB interfaces,LAN Video camera |
Software | XRF Analyzer Pro iCAL (Intelligent Calibration Logic) |
Accessories | Charger,AC adapter (battery included in the instrument) Consumables |
Available in two versions for field & offsite testing or laboratory & at-line testing, these new, portable spectrometers provide exceptional performance. Visit the SPECTROSCOUT Resource Center for more details and application examples.
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Mobility | Fixed |
Model Name/Number | NexION 1000 |
Weight | 150 kg |
Height | 75.0 cm |
Width | 81 cm |
Service Details:
Brand | PerkinElmer |
Model No / Item Code | PinAAcle 900F |
Wavelength Accuracy | +- 0.5 nm |
Wavelength Repeatability | +- 0.2 nm |
Usage / Application | Laboratory Use |
Warranty | 1 year |
Height | 64.0 cm |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
It features cutting-edge fiber optics to maximize light throughput for improved detection limits, as well as an eight-lamp mount, and automated flame and burner assembly optimization for enhanced productivity.
The PinAAcle 900F is controlled by the new Syngistix™ for AA Software, a workflow-based software designed to speed and simplify the journey from sample to results across a wide range of atomic absorption techniques.
Specifications
21 CFR Part 11 Compatible | Yes |
---|---|
Height | 64.0 cm |
Model Name | PinAAcle 900F |
Portable | No |
Product Brand Name | PinAAcle |
Warranty | 1 Year |
Weight | 94.0 kg |
Width | 95.0 cm |
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only.
List number |
r |
Disclaimer |
UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information:
Service Details:
Model Name/Number | Spectrum 2+ |
Usage/ Application | COVID-19 |
Brand | PerkinElmer |
Sample type | Alcohol based hand sanitizers |
Range | 4000 - 550 cm-1 |